SCBZ18-630/10 Three-Phase Two-Winding Dry-Type On-Load Tap-Changer Distribution Transformer

10kV Dry-Type Distribution Transformer Series

SCBZ18-630/10 Three-Phase Two-Winding Dry-Type On-Load Tap-Changer Distribution Transformer

The SCBZ18-630/10 is a three-phase, two-winding dry-type distribution transformer with epoxy resin casting and an on-load tap changer, rated at 630kVA and 10kV on the high-voltage side. It is designed for distribution systems with frequent voltage fluctuations and high requirements for supply continuity. The transformer features vacuum-cast epoxy resin insulation, providing excellent flame retardancy and pollution resistance. The core is made of high-quality cold-rolled grain-oriented silicon steel, and low-voltage windings use copper foil conductors. Equipped with a vacuum on-load tap changer and automatic voltage controller, it can regulate voltage under load without interrupting power supply.
  • Rated Capacity: 630 kVA
  • Rated Voltage Ratio: 10/0.4 kV
  • Connection Group: Dyn11
  • Cooling Method: AN
  • Energy Efficiency Class: N/A
  • Standard:IEC 60076, GB/T 10228-2023

Product Details

Learn more about our products

Product Model SCBZ18-630/10
No-Load Loss ≤0.89 kW
Rated Capacity 630 kVA
No-Load Current ≤0.7%
Phase 3-phase
Load Loss (120°C) ≤5.55 kW
Rated Voltage Ratio 10/0.4 kV
Short-Circuit Impedance 6%
HV Tapping Range ±4×2.5%
Temperature Rise Limit Winding ≤100K (F-class)
Rated Frequency 50 Hz
Noise (Sound Pressure Level) ≤52 dB(A)
Connection Group Dyn11 (Yyn0 available upon request)
Protection Degree IP20 (IP23 available)
Cooling Method AN
Standard IEC 60076, GB/T 10228-2023
Insulation Class F (155°C), LI75 AC28 / AC5
Energy Efficiency Class N/A
01.

Core advantages

On-Load Tap Changer (OLTC)
Equipped with a vacuum on-load tap changer, the transformer regulates voltage under load without interrupting power supply. Ideal for grids with frequent voltage fluctuations and critical load applications where continuous power supply is essential. The tapping range is 10±4×2.5% (9 positions).
Vacuum-Cast Epoxy Resin
High and low voltage windings are fully impregnated in F-class epoxy resin under vacuum conditions, providing excellent flame retardancy, moisture resistance, and pollution resistance. The transformer is maintenance-free and suitable for indoor installation, including distribution rooms and public buildings.
Low Partial Discharge & Low Temperature Rise
Optimized insulation structure and foil-wound windings ensure low partial discharge and low temperature rise. The transformer maintains stable operation under continuous load, with strong short-circuit withstand capability and long service life.
02.

Application scenarios

No data was found
01.

Authoritative Certification

CE
Our transformers are CE certified, ensuring full compliance with EU safety, health, and environmental standards.
UL
Our transformers are UL certified, confirming they meet rigorous ANSI/IEEE safety standards for North American market entry.
ASTA
Our transformers have obtained ASTA type-test certification, verifying IEC 60076 compliance.
EAC
Our transformers are EAC certified, ensuring compliance with safety and EMC regulations for the Eurasian market.
SASO
We provide SASO-compliant transformers and assist clients in obtaining the Batch Certificate of Conformity (CoC) through the SABER platform.
02.

Quality Assurance

Partner Factory Audit
Regular on-site audits of partner factories to verify ISO, CE, and UL certifications.
Full-Process Quality Control
From raw material inspection to pre-shipment final inspection, every unit is checked against specifications.
Comprehensive Test Reports
Each transformer includes a detailed factory test report. 100% full inspection before dispatch.
Third-Party Inspection Support
SGS, BV, or other accredited third-party inspection available upon customer request.
01.

Technical Documents

No data was found
02.

Certification Materials

No data was found

10kV Dry-Type Distribution Transformer Series – Full Specifications

10kV, 3-phase, 2-winding, dry-type, on-load tap-changer, distribution transformer, 315-2500kVA

ModelRated Capacity
(kVA)
HV (kV)HV Tapping
Range
LV (kV)Vector GroupNo-Load Loss
(kW)
Load Loss (kW)Impedance
Voltage (%)
B(100℃)F(120℃)H(145℃)
SCBZ18-315/1031510,10.5,11±4×2.5%0.4Dyn11,Yyn00.593.063.253.474
SCBZ14-315/1031510,10.5,11±4×2.5%0.4Dyn11,Yyn00.673.063.253.474
SCBZ12-315/1031510,10.5,11±4×2.5%0.4Dyn11,Yyn00.793.403.613.864
SCBZ18-400/1040010,10.5,11±4×2.5%0.4Dyn11,Yyn00.673.623.844.114
SCBZ14-400/1040010,10.5,11±4×2.5%0.4Dyn11,Yyn00.763.623.844.114
SCBZ12-400/1040010,10.5,11±4×2.5%0.4Dyn11,Yyn00.894.024.274.574
SCBZ18-500/1050010,10.5,11±4×2.5%0.4Dyn11,Yyn00.774.434.705.024
SCBZ14-500/1050010,10.5,11±4×2.5%0.4Dyn11,Yyn00.884.434.705.024
SCBZ12-500/1050010,10.5,11±4×2.5%0.4Dyn11,Yyn01.034.925.225.584
SCBZ18-630/1063010,10.5,11±4×2.5%0.4Dyn11,Yyn00.895.245.555.944
SCBZ14-630/1063010,10.5,11±4×2.5%0.4Dyn11,Yyn01.015.245.555.944
SCBZ12-630/1063010,10.5,11±4×2.5%0.4Dyn11,Yyn01.195.826.176.604
SCBZ18-800/1080010,10.5,11±4×2.5%0.4Dyn11,Yyn01.026.366.757.226
SCBZ14-800/1080010,10.5,11±4×2.5%0.4Dyn11,Yyn01.166.366.757.226
SCBZ12-800/1080010,10.5,11±4×2.5%0.4Dyn11,Yyn01.367.077.508.026
SCBZ18-1000/10100010,10.5,11±4×2.5%0.4Dyn11,Yyn01.197.457.908.456
SCBZ14-1000/10100010,10.5,11±4×2.5%0.4Dyn11,Yyn01.347.457.908.456
SCBZ12-1000/10100010,10.5,11±4×2.5%0.4Dyn11,Yyn01.588.288.789.396
SCBZ18-1250/10125010,10.5,11±4×2.5%0.4Dyn11,Yyn01.408.879.369.996
SCBZ14-1250/10125010,10.5,11±4×2.5%0.4Dyn11,Yyn01.598.879.369.996
SCBZ12-1250/10125010,10.5,11±4×2.5%0.4Dyn11,Yyn01.879.8610.4011.106
SCBZ18-1600/10160010,10.5,11±4×2.5%0.4Dyn11,Yyn01.6310.5311.1611.976
SCBZ14-1600/10160010,10.5,11±4×2.5%0.4Dyn11,Yyn01.8410.5311.1611.976
SCBZ12-1600/10160010,10.5,11±4×2.5%0.4Dyn11,Yyn02.1711.7012.4013.306
SCBZ18-2000/10200010,10.5,11±4×2.5%0.4Dyn11,Yyn02.0512.8713.6814.586
SCBZ14-2000/10200010,10.5,11±4×2.5%0.4Dyn11,Yyn02.3212.8713.6814.586
SCBZ12-2000/10200010,10.5,11±4×2.5%0.4Dyn11,Yyn02.7314.3015.2016.206
SCBZ18-2500/10250010,10.5,11±4×2.5%0.4Dyn11,Yyn02.3715.3916.2917.466
SCBZ14-2500/10250010,10.5,11±4×2.5%0.4Dyn11,Yyn02.6915.3916.2917.466
SCBZ12-2500/10250010,10.5,11±4×2.5%0.4Dyn11,Yyn03.1617.1018.1019.406
Note:
1.±4×2.5% is shown as the default tapping range in this table. Other tapping ranges are available upon request.
2.Other high and low voltages are available upon request.
3.Vector group options: Dyn11 or Yyn0. Other vector groups are available upon request.
4.Insulation class: B/F/H available. Load losses are shown for reference temperatures of 100°C (Class B), 120°C (Class F), and 145°C (Class H) respectively.
5.For IEC, ANSI, or other standards, or special frequency requirements, please contact us for a customized datasheet.

* For specific product requests, please Contact Us for customized solutions to your needs.

Contact information

Leave your contact information to download documents

Contact us

Please complete the form below to access and download our file resources.