Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

SCBZ18-12500/35 Three-Phase Two-Winding Dry-Type Air-Cooled On-Load Tap-Changer Power Transformer

35kV Dry-Type Power Transformer Series

SCBZ18-12500/35 Three-Phase Two-Winding Dry-Type Air-Cooled On-Load Tap-Changer Power Transformer

The SCBZ18-12500/35 is a three-phase, two-winding dry-type power transformer with epoxy resin casting and an on-load tap changer, rated at 12500kVA and 35kV on the high-voltage side, with a low-voltage side of 10.5kV (6.3kV, 6.6kV, and 11kV available upon request). It is designed for indoor applications where fire safety, moisture resistance, and continuous voltage regulation are essential. The transformer features vacuum-cast epoxy resin insulation, providing excellent flame retardancy and pollution resistance. The core is made of high-quality cold-rolled grain-oriented silicon steel, and low-voltage windings use copper foil conductors. Equipped with a vacuum on-load tap changer and automatic voltage controller, it can regulate voltage under load without interrupting power supply, making it suitable for grids with frequent voltage fluctuations. Typical applications include large industrial facilities, commercial complexes, data centers, substations, and other indoor locations where fire safety, reliable power supply, and stable voltage output are essential.
  • Rated Capacity: 12500 kVA
  • Rated Voltage Ratio: 35/10.5 kV
  • Connection Group: Yd11 (YNd11 available upon request)
  • Cooling Method: AN
  • Energy Efficiency Class: N/A
  • Standard:IEC 60076, GB/T 10228-2023

Product Details

Learn more about our products

Product Model SCBZ18-12500/35
No-Load Loss ≤11.025 kW
Rated Capacity 12500 kVA
No-Load Current ≤0.35%
Phase 3-phase
Load Loss (120°C) ≤59.85 kW
Rated Voltage Ratio 35/10.5 kV
Short-Circuit Impedance 9%
HV Tapping Range ±4×2.5%
Temperature Rise Limit Winding ≤100K (F-class)
Rated Frequency 50 Hz
Noise (Sound Pressure Level) ≤65 dB(A)
Connection Group Yd11 (YNd11 available upon request)
Protection Degree IP20 (IP23 available)
Cooling Method AN
Standard IEC 60076, GB/T 10228-2023
Insulation Class F (155°C), LI170 AC70 / LI75 AC35
Energy Efficiency Class N/A
01.

Core advantages

On-Load Tap Changer (OLTC)
Equipped with a vacuum on-load tap changer, the transformer regulates voltage under load without interrupting power supply. Ideal for grids with frequent voltage fluctuations and critical load applications where continuous power supply is essential. The tapping range is 35±4×2.5% (9 positions).
Vacuum-Cast Epoxy Resin
High and low voltage windings are fully impregnated in F-class epoxy resin under vacuum conditions, providing excellent flame retardancy, moisture resistance, and pollution resistance. The transformer is maintenance-free and suitable for indoor installation, including basements, tunnels, and other enclosed spaces.
Low Loss Design & Smart Control
Designed with low-loss SCBZ18-level core and winding. Actual measured losses are typically lower than reference values, and detailed test data can be provided upon request. Can be equipped with an automatic voltage controller for real-time voltage monitoring and automatic tap position adjustment, with communication interfaces reserved for integration into plant monitoring or smart distribution systems.
02.

Application scenarios

No data was found
01.

Authoritative Certification

CE
Our transformers are CE certified, ensuring full compliance with EU safety, health, and environmental standards.
UL
Our transformers are UL certified, confirming they meet rigorous ANSI/IEEE safety standards for North American market entry.
ASTA
Our transformers have obtained ASTA type-test certification, verifying IEC 60076 compliance.
EAC
Our transformers are EAC certified, ensuring compliance with safety and EMC regulations for the Eurasian market.
SASO
We provide SASO-compliant transformers and assist clients in obtaining the Batch Certificate of Conformity (CoC) through the SABER platform.
02.

Quality Assurance

Partner Factory Audit
Regular on-site audits of partner factories to verify ISO, CE, and UL certifications.
Full-Process Quality Control
From raw material inspection to pre-shipment final inspection, every unit is checked against specifications.
Comprehensive Test Reports
Each transformer includes a detailed factory test report. 100% full inspection before dispatch.
Third-Party Inspection Support
SGS, BV, or other accredited third-party inspection available upon customer request.
01.

Technical Documents

No data was found
02.

Certification Materials

No data was found

35kV Dry-Type Power Transformer Series – Full Specifications

35kV, 3-phase, 2-winding, dry-type, on-load tap-changer, power transformer, 2000-25000kVA

ModelRated Capacity
(kVA)
HV (kV)HV Tapping
Range
LV (kV)Vector GroupNo-Load Loss
(kW)
Load Loss (kW)Impedance
Voltage (%)
B(100℃)F(120℃)H(145℃)
SCBZ18-2000/35200035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd113.03816.11017.10018.2707
SCBZ14-2000/35200035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd113.44316.11017.10018.2707
SCBZ12-2000/35200035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd113.64517.90019.00020.3007
SCBZ18-2500/35250035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd113.51819.17020.34021.7807
SCBZ14-2500/35250035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd113.98719.17020.34021.7807
SCBZ12-2500/35250035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd114.22121.30022.60024.2007
SCBZ18-3150/35315035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd114.25321.60022.86024.4808
SCBZ14-3150/35315035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd114.82021.60022.86024.4808
SCBZ12-3150/35315035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd115.10324.00025.40027.2008
SCBZ18-4000/35400035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd114.98025.83027.36029.3408
SCBZ14-4000/35400035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd115.64425.83027.36029.3408
SCBZ12-4000/35400035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd115.97628.70030.40032.6008
SCBZ18-5000/35500035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd115.88830.60032.49034.7408
SCBZ14-5000/35500035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd116.67330.60032.49034.7408
SCBZ12-5000/35500035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd117.06534.00036.10038.6008
SCBZ18-6300/35630035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd116.95335.46037.62040.2308
SCBZ14-6300/35630035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd117.88035.46037.62040.2308
SCBZ12-6300/35630035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd118.34339.40041.80044.7008
SCBZ18-8000/35800035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd117.95040.32042.75045.7209
SCBZ14-8000/35800035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd119.01040.32042.75045.7209
SCBZ12-8000/35800035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd119.54044.80047.50050.8009
SCBZ18-10000/351000035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd119.07548.51051.39055.0809
SCBZ14-10000/351000035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd1110.28548.51051.39055.0809
SCBZ12-10000/351000035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd1110.89053.90057.10061.2009
SCBZ18-12500/351250035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd1111.02556.43059.85063.9909
SCBZ14-12500/351250035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd1112.49556.43059.85063.9909
SCBZ12-12500/351250035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd1113.23062.70066.50071.1009
SCBZ18-16000/351600035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd1113.57566.42070.38075.3309
SCBZ14-16000/351600035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd1115.38566.42070.38075.3309
SCBZ12-16000/351600035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd1116.29073.80078.20083.7009
SCBZ18-20000/352000035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd1116.05074.70079.20084.78010
SCBZ16-20000/352000035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd1118.19074.70079.20084.78010
SCBZ12-20000/352000035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd1119.26083.00088.00094.20010
SCBZ18-25000/352500035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd1118.90088.38093.60099.90010
SCBZ16-25000/352500035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd1121.42088.38093.60099.90010
SCBZ12-25000/352500035,36,37,38.5±4×2.5%6,6.3,10,10.5,11Dyn11,Yd1122.68098.200104.000111.00010
Note:
1.±4×2.5% is shown as the default tapping range in this table. Other tapping ranges are available upon request.
2.Other high and low voltages are available upon request.
3.Other vector groups are available upon request.
4.Insulation class: B/F/H available. Load losses are shown for reference temperatures of 100°C (Class B), 120°C (Class F), and 145°C (Class H) respectively.
5.For IEC, ANSI, or other standards, or special frequency requirements, please contact us for a customized datasheet.

* For specific product requests, please Contact Us for customized solutions to your needs.

Contact information

Leave your contact information to download documents

Contact us

Please complete the form below to access and download our file resources.