SCB18-3150/35-NX1 Three-Phase Two-Winding Dry-Type Off-Circuit Tap-Changer Renewable Energy Transformer

35kV Dry-Type Renewable Energy Transformer Series

SCB18-3150/35-NX1 Three-Phase Two-Winding Dry-Type Off-Circuit Tap-Changer Renewable Energy Transformer

The SCB18-3150/35-NX1 is a three-phase, two-winding dry-type transformer with epoxy resin casting and an off-circuit tap changer, rated at 3150kVA and 35kV on the high-voltage side. It is specifically designed for large-scale renewable energy applications (PV, wind, and energy storage), stepping up the low-voltage output from inverters or PCS (0.4–1.14kV) to a 35kV collector grid. Designed to meet Class 1 energy efficiency (NX1) under GB 20052-2024, it delivers exceptionally low no-load loss for continuous station operation. The transformer features vacuum-cast F-class epoxy resin insulation, offering excellent flame retardancy, moisture resistance, and maintenance-free operation. Low-voltage windings use copper foil conductors to handle high currents, and the core is made of high-grade grain-oriented silicon steel, ensuring low partial discharge and strong short-circuit withstand capability. It is particularly suitable for the high-capacity, high-reliability requirements of large renewable energy bases and offshore wind applications.
  • Rated Capacity: 3150 kVA
  • Rated Voltage Ratio: 35~38.5 / 0.4-1.14 kV
  • Connection Group: Dyn11
  • Cooling Method: AN / AF
  • Energy Efficiency Class: NX1
  • Standard:IEC 60076, GB/T 10228-2023, GB 20052-2024

Product Details

Learn more about our products

Product Model SCB18-3150/35-NX1
No-Load Loss ≤3.5 kW
Rated Capacity 3150 kVA
No-Load Current ≤0.6%
Phase Three-phase
Load Loss (120°C) ≤22.1 kW
Rated Voltage Ratio 35~38.5/0.4~1.14 kV
Short-Circuit Impedance 6~14%
HV Tapping Range ±2×2.5%
Temperature Rise Limit Winding ≤100K (F-class)
Rated Frequency 50 Hz
Noise (Sound Pressure Level) ≤65dB(A)
Connection Group Dyn11
Protection Degree IP20 (IP54 available)
Cooling Method AN / AF
Standard IEC 60076, GB/T 10228-2023, GB 20052-2024
Insulation Class F (155°C), LI170 AC70 / AC5
Energy Efficiency Class NX1
01.

Core advantages

Class 1 Energy Efficiency (NX1)
Complies with GB 20052-2024 Class 1 energy efficiency standard for 35kV renewable energy dry-type transformers. Its exceptionally low no-load loss directly reduces the auxiliary power consumption of the station, ensuring more generated electricity is delivered to the grid. For large-scale bases that operate continuously, the energy savings over the service life are substantial. Actual measured losses are typically lower than the standard limits; detailed test reports can be provided upon request.
High-Capacity Dry-Type Safety
At 3150kVA, this transformer provides the high capacity required for large renewable energy collection systems while retaining the inherent safety of dry-type construction—no oil leakage, no fire risk. The F-class epoxy casting provides excellent moisture and pollution resistance. Partial discharge is controlled at a very low level (≤5 pC), ensuring long-term insulation reliability in humid, dusty, or coastal environments. This makes it particularly suitable for large PV/wind/storage stations and offshore wind platforms with strict fire safety and environmental requirements.
Optimized for Harmonics, High-Current & Overload
The low-voltage side is designed with copper foil windings to handle the high currents from large inverters and PCS. The electromagnetic design is optimized to withstand harmonics generated by power electronics. With forced-air cooling (AF), the transformer can handle short-term overloads, making it suitable for the frequent load fluctuations and impact loads typical of large renewable energy stations and offshore wind turbines.
02.

Application scenarios

No data was found
01.

Authoritative Certification

CE
Our transformers are CE certified, ensuring full compliance with EU safety, health, and environmental standards.
UL
Our transformers are UL certified, confirming they meet rigorous ANSI/IEEE safety standards for North American market entry.
ASTA
Our transformers have obtained ASTA type-test certification, verifying IEC 60076 compliance.
EAC
Our transformers are EAC certified, ensuring compliance with safety and EMC regulations for the Eurasian market.
SASO
We provide SASO-compliant transformers and assist clients in obtaining the Batch Certificate of Conformity (CoC) through the SABER platform.
02.

Quality Assurance

Partner Factory Audit
Regular on-site audits of partner factories to verify ISO, CE, and UL certifications.
Full-Process Quality Control
From raw material inspection to pre-shipment final inspection, every unit is checked against specifications.
Comprehensive Test Reports
Each transformer includes a detailed factory test report. 100% full inspection before dispatch.
Third-Party Inspection Support
SGS, BV, or other accredited third-party inspection available upon customer request.
01.

Technical Documents

No data was found
02.

Certification Materials

No data was found

35kV Dry-Type Renewable Energy Transformer Series – Full Specifications

35kV, 3-phase, 2-winding, dry-type, off-circuit tap-changer, renewable energy transformer, 35-38.5kV / 0.4-1.14kV, 1000-10000kVA

ModelRated Capacity
(kVA)
HV (kV)HV Tapping
Range
LV (kV)Vector GroupNo-Load Loss
(kW)
Load Loss (kW)Impedance
Voltage (%)
B(100℃)F(120℃)H(145℃)
SCB18-1000/35-NX1100035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn111.4008.8009.40010.1006~14
SCB14-1000/35-NX2100035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn111.6008.8009.40010.1006~14
SCB12-1000/35-NX3100035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn111.7009.80010.40011.2006~14
SCB18-1250/35-NX1125035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn111.60010.70011.40012.2006~14
SCB14-1250/35-NX2125035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn111.80010.70011.40012.2006~14
SCB12-1250/35-NX3125035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn112.00011.90012.70013.5006~14
SCB18-1600/35-NX1160035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn111.90013.10013.90014.9006~14
SCB14-1600/35-NX2160035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn112.10013.10013.90014.9006~14
SCB12-1600/35-NX3160035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn112.30014.50015.40016.5006~14
SCB18-2000/35-NX1200035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn112.20015.40016.40017.5006~14
SCB14-2000/35-NX2200035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn112.50015.40016.40017.5006~14
SCB12-2000/35-NX3200035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn112.70017.10018.20019.4006~14
SCB18-2500/35-NX1250035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn112.60018.50019.60021.0006~14
SCB14-2500/35-NX2250035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn112.90018.50019.60021.0006~14
SCB12-2500/35-NX3250035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn113.20020.50021.80023.3006~14
SCB18-3000/35-NX1300035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn113.20020.30021.60023.1006~14
SCB14-3000/35-NX2300035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn113.50020.30021.60023.1006~14
SCB12-3000/35-NX3300035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn113.90022.60024.00025.6006~14
SCB18-3150/35-NX1315035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn113.50020.70022.10023.5006~14
SCB14-3150/35-NX2315035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn113.90020.70022.10023.5006~14
SCB12-3150/35-NX3315035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn114.30023.10024.50026.1006~14
SCB18-4000/35-NX1400035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn114.10024.90026.50028.2006~14
SCB14-4000/35-NX2400035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn114.50024.90026.50028.2006~14
SCB12-4000/35-NX3400035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn115.00027.70029.40031.3006~14
SCB18-4500/35-NX1450035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn114.40027.40029.10031.1006~14
SCB14-4500/35-NX2450035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn114.90027.40029.10031.1006~14
SCB12-4500/35-NX3450035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn115.40030.40032.30034.5006~14
SCB18-5000/35-NX1500035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn114.80029.60031.40033.6006~14
SCB14-5000/35-NX2500035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn115.40029.60031.40033.6006~14
SCB12-5000/35-NX3500035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn116.00032.80034.90037.3006~14
SCB18-6300/35-NX1630035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn115.70034.60036.70039.2006~14
SCB14-6300/35-NX2630035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn116.40034.60036.70039.2006~14
SCB12-6300/35-NX3630035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn117.10038.40040.80043.6006~14
SCB18-8000/35-NX1800035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn116.90041.70044.30047.3006~14
SCB14-8000/35-NX2800035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn117.60041.70044.30047.3006~14
SCB12-8000/35-NX3800035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn118.50046.30049.20052.6006~14
SCB18-10000/35-NX11000035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn118.20049.00052.10055.7006~14
SCB14-10000/35-NX21000035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn119.10049.00052.10055.7006~14
SCB12-10000/35-NX31000035, 38.5±2×2.5%0.4, 0.69, 0.8, 1.14Dyn1110.20054.50057.90061.9006~14
Note:
1.±2×2.5% is shown as the default tapping range in this table. Other tapping ranges are available upon request.
2.Other high and low voltages are available upon request.
3.Other vector groups are available upon request.
4.Efficiency classes (NX1/NX2/NX3) are in accordance with GB 20052-2024 for renewable energy transformers (PV, wind, energy storage) of 500kVA and above.
5.For IEC, ANSI, or other standards, or special frequency requirements, please contact us for a customized datasheet.

* For specific product requests, please Contact Us for customized solutions to your needs.