S22-10000/66-NX1 Three-Phase Oil-Immersed Off-Circuit Tap-Changer Power Transformer

66kV Oil-Immersed Power Transformer Series

S22-10000/66-NX1 Three-Phase Oil-Immersed Off-Circuit Tap-Changer Power Transformer

The S22-10000/66-NX1 is a three-phase oil-immersed power transformer with a rated capacity of 10000kVA and a high-voltage side rating of 66kV. It is designed with S22 loss level, achieving Class 1 energy efficiency (NX1) according to GB 20052-2024, with no-load loss of 5.8 kW and load loss of 43.0 kW meeting the highest efficiency limits for 66kV power transformers. The transformer features a robust oil-immersed structure with high reliability, low loss, and strong short-circuit withstand capability. The core is made of high-quality cold-rolled grain-oriented silicon steel, and windings use oxygen-free copper conductors. It is suitable for 66kV power systems, providing reliable and energy-efficient power supply for substations, large industrial parks, and urban power grids.
  • Rated Capacity: 10000 kVA
  • Rated Voltage Ratio: 66/10.5 kV
  • Connection Group: YNd11
  • Cooling Method: ONAN
  • Energy Efficiency Class: NX1
  • Standard:IEC 60076, GB/T 6451-2023

Product Details

Learn more about our products

Product Model S22-10000/66-NX1
No-Load Loss ≤5.8 kW
Rated Capacity 10000 kVA
No-Load Current ≤0.45%
Phase 3-phase
Load Loss (75°C) ≤43 kW
Rated Voltage Ratio 66/10.5 kV
Short-Circuit Impedance 9.0%
HV Tapping Range ±2×2.5%
Temperature Rise Limit Top oil ≤55K, Winding ≤65K
Rated Frequency 50 Hz
Noise (Sound Pressure Level) ≤60 dB(A)
Connection Group YNd11
Protection Degree IP54
Cooling Method ONAN
Standard IEC 60076, GB/T 6451-2023
Insulation Class A, LI325 AC140 / LI75 AC35
Energy Efficiency Class NX1
01.

Core advantages

Class 1 Energy Efficiency (NX1)
Complies with GB 20052-2024 Class 1 energy efficiency standard. No-load loss is reduced by more than 30% and load loss by more than 20% compared with conventional models, significantly reducing long-term operating costs
High Reliability & Strong Short-Circuit Withstand
Optimized core and winding design, combined with a robust oil-immersed structure, ensures stable operation under heavy loads with strong short-circuit resistance and long service life.
Low Loss Design (S22 Level)
Optimized core and coil design achieves low no-load and load losses, ensuring reliable and efficient operation for substations, industrial and mining enterprises, and power transmission applications.
02.

Application scenarios

No data was found
01.

Authoritative Certification

CE
Our transformers are CE certified, ensuring full compliance with EU safety, health, and environmental standards.
UL
Our transformers are UL certified, confirming they meet rigorous ANSI/IEEE safety standards for North American market entry.
ASTA
Our transformers have obtained ASTA type-test certification, verifying IEC 60076 compliance.
EAC
Our transformers are EAC certified, ensuring compliance with safety and EMC regulations for the Eurasian market.
SASO
We provide SASO-compliant transformers and assist clients in obtaining the Batch Certificate of Conformity (CoC) through the SABER platform.
02.

Quality Assurance

Partner Factory Audit
Regular on-site audits of partner factories to verify ISO, CE, and UL certifications.
Full-Process Quality Control
From raw material inspection to pre-shipment final inspection, every unit is checked against specifications.
Comprehensive Test Reports
Each transformer includes a detailed factory test report. 100% full inspection before dispatch.
Third-Party Inspection Support
SGS, BV, or other accredited third-party inspection available upon customer request.
01.

Technical Documents

No data was found
02.

Certification Materials

No data was found

66kV Oil-Immersed Power Transformer Series – Full Specifications

66kV, 3-phase, 2-winding, oil-immersed, off-circuit tap-changer, power transformer, 630-63000kVA

ModelRated Capacity
(kVA)
HV (kV)HV Tapping
Range
LV (kV)Vector GroupNo-Load Loss
(kW)
Load Loss
(75°C) (kW)
Impedance
Voltage (%)
S22-630/6663066,66,69±5%6.3,6.6,10.5Yd110.6726.4138
S20-630/6663066,66,69±5%6.3,6.6,10.5Yd110.7686.4138
S18-630/6663066,66,69±5%6.3,6.6,10.5Yd110.9606.7508
S22-800/6680066,66,69±5%6.3,6.6,10.5Yd110.8407.6768
S20-800/6680066,66,69±5%6.3,6.6,10.5Yd110.9607.6768
S18-800/6680066,66,69±5%6.3,6.6,10.5Yd111.2008.0808
S22-1000/66100066,66,69±5%6.3,6.6,10.5Yd110.9528.8458
S20-1000/66100066,66,69±5%6.3,6.6,10.5Yd111.0888.8458
S18-1000/66100066,66,69±5%6.3,6.6,10.5Yd111.3609.3108
S22-1250/66125066,66,69±5%6.3,6.6,10.5Yd111.12010.7358
S20-1250/66125066,66,69±5%6.3,6.6,10.5Yd111.28010.7358
S18-1250/66125066,66,69±5%6.3,6.6,10.5Yd111.60011.3008
S22-1600/66160066,66,69±5%6.3,6.6,10.5Yd111.34412.6358
S20-1600/66160066,66,69±5%6.3,6.6,10.5Yd111.53612.6358
S18-1600/66160066,66,69±5%6.3,6.6,10.5Yd111.92013.3008
S22-2000/66200066,66,69±5%6.3,6.6,10.5Yd111.56815.0108
S20-2000/66200066,66,69±5%6.3,6.6,10.5Yd111.79215.0108
S18-2000/66200066,66,69±5%6.3,6.6,10.5Yd112.24015.8008
S22-2500/66250066,66,69±5%6.3,6.6,10.5Yd111.90417.6708
S20-2500/66250066,66,69±5%6.3,6.6,10.5Yd112.17617.6708
S18-2500/66250066,66,69±5%6.3,6.6,10.5Yd112.72018.6008
S22-3150/66-NX1315066,66,69±5%6.3,6.6,10.5YNd112.20020.7008
S20-3150/66-NX2315066,66,69±5%6.3,6.6,10.5YNd112.60020.7008
S18-3150/66-NX3315066,66,69±5%6.3,6.6,10.5YNd113.20021.9008
S22-4000/66-NX1400066,66,69±5%6.3,6.6,10.5YNd112.60024.6008
S20-4000/66-NX2400066,66,69±5%6.3,6.6,10.5YNd113.10024.6008
S18-4000/66-NX3400066,66,69±5%6.3,6.6,10.5YNd113.80025.9008
S22-5000/66-NX1500066,66,69±5%6.3,6.6,10.5YNd113.10027.6008
S20-5000/66-NX2500066,66,69±5%6.3,6.6,10.5YNd113.70027.6008
S18-5000/66-NX3500066,66,69±5%6.3,6.6,10.5YNd114.60029.2008
S22-6300/66-NX1630066,66,69±2×2.5%6.3,6.6,10.5YNd114.00030.8009
S20-6300/66-NX2630066,66,69±2×2.5%6.3,6.6,10.5YNd114.70030.8009
S18-6300/66-NX3630066,66,69±2×2.5%6.3,6.6,10.5YNd115.80032.5009
S22-8000/66-NX1800066,66,69±2×2.5%6.3,6.6,10.5YNd114.90036.5009
S20-8000/66-NX2800066,66,69±2×2.5%6.3,6.6,10.5YNd115.80036.5009
S18-8000/66-NX3800066,66,69±2×2.5%6.3,6.6,10.5YNd117.10038.5009
S22-10000/66-NX11000066,66,69±2×2.5%6.3,6.6,10.5YNd115.80043.0009
S20-10000/66-NX21000066,66,69±2×2.5%6.3,6.6,10.5YNd116.80043.0009
S18-10000/66-NX31000066,66,69±2×2.5%6.3,6.6,10.5YNd118.40045.4009
S22-12500/66-NX11250066,66,69±2×2.5%6.3,6.6,10.5YNd116.80051.1009
S20-12500/66-NX21250066,66,69±2×2.5%6.3,6.6,10.5YNd118.10051.1009
S18-12500/66-NX31250066,66,69±2×2.5%6.3,6.6,10.5YNd119.90054.0009
S22-16000/66-NX11600066,66,69±2×2.5%6.3,6.6,10.5YNd118.30062.8009
S20-16000/66-NX21600066,66,69±2×2.5%6.3,6.6,10.5YNd119.80062.8009
S18-16000/66-NX31600066,66,69±2×2.5%6.3,6.6,10.5YNd1112.00066.3009
S22-20000/66-NX12000066,66,69±2×2.5%6.3,6.6,10.5YNd119.70076.1009
S20-20000/66-NX22000066,66,69±2×2.5%6.3,6.6,10.5YNd1111.40076.1009
S18-20000/66-NX32000066,66,69±2×2.5%6.3,6.6,10.5YNd1114.10080.4009
S22-25000/66-NX12500066,66,69±2×2.5%6.3,6.6,10.5YNd1111.40090.0009
S20-25000/66-NX22500066,66,69±2×2.5%6.3,6.6,10.5YNd1113.50090.0009
S18-25000/66-NX32500066,66,69±2×2.5%6.3,6.6,10.5YNd1116.60095.0009
S22-31500/66-NX13150066,66,69±2×2.5%6.3,6.6,10.5YNd1113.500108.0009
S20-31500/66-NX23150066,66,69±2×2.5%6.3,6.6,10.5YNd1116.000108.0009
S18-31500/66-NX33150066,66,69±2×2.5%6.3,6.6,10.5YNd1119.700114.0009
S22-40000/66-NX14000066,66,69±2×2.5%6.3,6.6,10.5YNd1116.200126.9009
S20-40000/66-NX24000066,66,69±2×2.5%6.3,6.6,10.5YNd1119.100126.9009
S18-40000/66-NX34000066,66,69±2×2.5%6.3,6.6,10.5YNd1123.500134.0009
S22-50000/66-NX15000066,66,69±2×2.5%6.3,6.6,10.5YNd1119.400150.3009
S20-50000/66-NX25000066,66,69±2×2.5%6.3,6.6,10.5YNd1122.900150.3009
S18-50000/66-NX35000066,66,69±2×2.5%6.3,6.6,10.5YNd1128.200158.7009
S22-63000/66-NX16300066,66,69±2×2.5%6.3,6.6,10.5YNd1122.900178.2009
S20-63000/66-NX26300066,66,69±2×2.5%6.3,6.6,10.5YNd1127.000178.2009
S18-63000/66-NX36300066,66,69±2×2.5%6.3,6.6,10.5YNd1133.300188.1009
Note:
1.Tapping range options: ±2×2.5% or ±5% are shown as defaults in this table. Other tapping ranges are available upon request.
2.Other high and low voltages are available upon request.
3.Other vector groups are available upon request.
4.Efficiency classes (NX1/NX2/NX3) apply to 3150kVA and above, in accordance with GB 20052-2024.
5.For IEC, ANSI, or other standards, or special frequency requirements, please contact us for a customized datasheet.

* For specific product requests, please Contact Us for customized solutions to your needs.

Contact information

Leave your contact information to download documents

Contact us

Please complete the form below to access and download our file resources.